Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Heliyon ; 10(7): e27911, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38560271

RESUMEN

The structural and functional changes of the left atrium (LA)are important for maintaining the filling of the left ventricle (LV), whether the hemodynamics is stable or not, and are valuable for evaluating LV diastolic dysfunction and grading the severity. Studies over the past decade have shown that LA structural alterations are linked to several cardiovascular disorders, and LA enlargement has been identified as a strong predictor of several cardiovascular diseases. However, LA structural or volumetric abnormalities are commonly seen in the advanced stages of disease and do not adequately represent functional changes throughout the cardiac cycle. In recent years, LA strain obtained using cardiac magnetic resonance feature tracking (CMR-FT)technology has been shown to provide early monitoring of LA tension damage while also comprehensively reflecting LA functional changes in three phases, providing deeper insights into cardiovascular disease risk, prognosis of cardiovascular disease, and evaluation of therapeutic efficacy. When compared to the ultrasound speckle tracking approach, the CMR-FT technique provides improved spatial resolution, repeatability, and reproducibility. We report a comprehensive review of the most recent studies on CMR-LA strain in the past five years, including normal reference values, early detection of disease, incremental diagnosis, improvement of risk stratification, assessment of the value of atrial-ventricular hemodynamics and coupled injury, major adverse cardiovascular events and prognostic value, as well as future research perspectives and current limitations, aiming at providing an objective reference for the further exploration of the value of the application of CMR-LA strain in various cardiac disorders.

2.
Sci Total Environ ; 924: 171561, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38458472

RESUMEN

Ambient ozone (O3) is recognized as a significant air pollutant with implications for cardiorespiratory health, yet the effects of indoor O3 exposure have received less consideration. Furthermore, while sleep occupies one-third of life, research on the health consequences of O3 exposure during this crucial period is scarce. This study aimed to investigate associations of indoor O3 during sleep with cardiorespiratory function and potential predisposing factors. A prospective study among 81 adults was conducted in Beijing, China. Repeated measurements of cardiorespiratory indices reflecting lung function, airway inflammation, cardiac autonomic function, blood pressure, systemic inflammation, platelet and glucose were performed on each subject. Real-time concentrations of indoor O3 during sleep were monitored. Associations of O3 with cardiorespiratory indices were evaluated using linear mixed-effect model. Effect modification by baseline lifestyles (diet, physical activity, sleep-related factors) and psychological status (stress and depression) were investigated through interaction analysis. The average indoor O3 concentration during sleep was 20.3 µg/m3, which was well below current Chinese indoor air quality standard of 160 µg/m3. O3 was associated with most respiratory indicators of decreased airway function except airway inflammation; whereas the cardiovascular effects were only manifested in autonomic dysfunction and not in others. An interquartile range increases in O3 at 6-h average was associated with changes of -3.60 % (95 % CI: -6.19 %, -0.93 %) and -9.60 % (95 % CI: -14.53 %, -4.39 %) in FVC and FEF25-75, respectively. Further, stronger effects were noted among participants with specific dietary patterns, poorer sleep and higher level of depression. This study provides the first general population-based evidence that low-level exposure to indoor O3 during sleep has greater effects on the respiratory system than on the cardiovascular system. Our findings identify the respiratory system as an important target for indoor O3 exposure, and particularly highlight the need for greater awareness of indoor air quality, especially during sleep.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Ozono , Adulto , Humanos , Contaminación del Aire/análisis , Estudios Prospectivos , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Ozono/efectos adversos , Ozono/análisis , China , Inflamación , Material Particulado/análisis , Exposición a Riesgos Ambientales/análisis
3.
World J Cardiol ; 15(11): 609-614, 2023 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-38058400

RESUMEN

BACKGROUND: Danon disease (DD), in which mutations in the X-linked lysosome-associated membrane protein-2 (LAMP-2) gene result in hypertrophic cardiomyopathy, is a rare disease, reported primarily in small samples or cases. However, with the development of cardiac magnetic resonance imaging and genetic technology in recent years, the number of reports has increased. CASE SUMMARY: We report a case of DD in an adolescent male patient, confirmed by genetic testing. The patient was admitted to our hospital with complaints of a three-year history of chest tightness and shortness of breath. His preliminary clinical diagnosis is hypertrophic cardiomyopathy. Our report includes the patient's clinical course from hospital admission to death, step-by-step diagnosis, treatment course, and noninvasive imaging features. We highlight how a noninvasive diagnostic approach, based solely on clinical and imaging "red flags" for DD, can be used to achieve a diagnosis of DD with a high degree of confidence. CONCLUSION: DD is a very dangerous cardiomyopathy, and it is necessary to achieve early diagnosis and treatment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...